Genie S-40 Service Manual page 173

Hide thumbs Also See for S-40:
Table of Contents

Advertisement

February 2014
SPN = Suspect Parameter Number / FMI - Failure Mode Identifier / KWP = Keyword Protocol
SPN
FMI KWP
523922 7
1262 Burner Shut Off Valve;
blocked closed
523922 7
1264 Burner Shut Off Valve;
blocked open
523929 0
109
Fuel Balance Control integrator
injector 1 (in firing order);
maximum value exceeded
523929 1
115
Fuel Balance Control integrator
injector 1 (in firing order);
minimum value exceeded
523930 0
110
Fuel Balance Control integrator
injector 2 (in firing order);
maximum value exceeded
523930 1
116
Fuel Balance Control integrator
injector 2 (in firing order);
minimum value exceeded
523931 0
111
Fuel Balance Control integrator
injector 3 (in firing order);
maximum value exceeded
523931 1
117
Fuel Balance Control integrator
injector 3 (in firing order);
minimum value exceeded
523932 0
112
Fuel Balance Control integrator
injector 4 (in firing order);
maximum value exceeded
523932 1
118
Fuel Balance Control integrator
injector 4 (in firing order);
minimum value exceeded
523935 12
168
Timeout Error of CAN-Transmit-
Frame EEC3VOL1; Engine
send messages
Part No. 826364
Description
S-40 • S-45 • S-40 TRAX • S-45 TRAX
Deutz D 2.9 L4 Engine Fault Codes
SPN
FMI KWP
523936 12
169
Timeout Error of CAN-Transmit-
Frame EEC3VOL2; Engine
send messages
523946 0
1158 Zerofuel calibration injector 1
(in firing order);
maximum value exceeded
523946 1
1164 Zerofuel calibration injector 1
(in firing order);
minimum value exceeded
523947 0
1159 Zerofuel calibration injector 2
(in firing order);
maximum value exceeded
523947 1
1165 Zerofuel calibration injector 2
(in firing order);
minimum value exceeded
523948 0
1160 Zerofuel calibration injector 3
(in firing order);
maximum value exceeded
523948 1
1166 Zerofuel calibration injector 3
(in firing order);
minimum value exceeded
523949 0
1161 Zerofuel calibration injector 4
(in firing order);
maximum value exceeded
523949 1
1167 Zerofuel calibration injector 4
(in firing order);
minimum value exceeded
523960 0
1011 Physical range check high for
EGR cooler downstream temp.
Section 5 • Fault Codes
Description
5 - 21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-45 traxS-45

Table of Contents