Chapter 14 Troubleshooting
To set the parameters for the System Status Sanity check, click the LED Settings tab.
3
The LED Settings record appears.

Figure 72 System Status Monitor LED Settings record

Table 39
lists the values on the LED Settings screen.

Table 39 LED Display screen settings

Attribute
Values
Version
Read only.
Reset
Yes, No, N/A
Sanity Time
60-255
Default: 240
Timeouts
0-254
Default: 10

Emergency telephone does not function

If the emergency telephone is connected to the system, use the following procedure:
Check the power LED on the ASM 8 to check that the ASM 8 is receiving power.
1
Check that the emergency telephone has dial tone.
2
Check the external line and emergency telephone connections.
3
To avoid damage to the emergency telephone, connect the telephone directly to the external
4
line and check for dial tone.
Replace the MSC.
5
N0008587 01
Description
The current version of the LED monitoring application.
Use Yes to allow the system status monitor board to reset the
computing platform in the event that the sanity check fails the
user set parameters.
The time in seconds between sanity checks.
The number of sanity checks that must fail before the system
status monitor sends a reset signal to the computing platform.