Connecting when there is an IP address conflict

If you cannot use the default IP address, you must change the IP address of the BCM1000 through
one of these connections:
a terminal and a null modem cable. Refer to
a computer and an Ethernet crossover cable. Refer to
page
130.
After you set the initial parameters, you can connect to the Unified Manager through the network
to complete the system setup using the Quick Start Wizard.
If you do not have a network connection, you can also access a Quick Start Wizard through a serial
link.
For detailed information about configuring the BCM1000 using the Unified Manager, refer to the
Business Communications Manager Programming Operations Guide

Using a null modem serial cable

You must use a null modem cable connection to the BCM1000 if the default IP address is not
compatible with your LAN or WAN network.
Required equipment:
null modem cable
VT100-compatible terminal or a computer that has a terminal program such as Hyperterminal
Warning: Your terminal must be VT100-compatible and must support the VT100
National Character set. If the terminal does not support the National Character set, the text
displays incorrectly.
Setting up the null modem cable
Table 33
shows the correct wiring for the BCM1000 serial port of the null modem cable.

Table 33 Serial port pinout

Figure 49 Serial pinout

1 2 3 4 5
6 7 8 9
Transmission parameters:
Pin
Signal
1
Data Carrier Detect (DCD)
2
* Serial data in (RX)
3
* Serial data out (TX)
4
Data Terminal Ready (DTR)
5
* Ground
* required connections
Chapter 9 Starting the system 127
"Using a null modem serial cable" on page
"Using an Ethernet crossover cable" on
Pin
6
7
8
9
Installation and Maintenance Guide
127.
Signal
Data Set Ready (DSR)
Request to Send (RTS)
Clear to Send (CTS)
Ring Indicator (RI)