138 Chapter 10 Wiring the modules

Wiring media bay modules to internal connections

After you have the trunk modules wired, you can install the wiring to the station modules. These
are the modules which connect to the internal telephone sets.
All station module wiring uses 25-pair cable with a female amphenol connector at the media bay
module end.
Note: DSM 32 modules require two 25-pair cables.
Follow these steps to connect the wiring for the DSM 16, DSM 32, ASM 8, GASM8, or 4X16
modules:
Wire 16 wire pairs from the amphenol connector to the local connecting blocks so they
1
connect to the 16 station sets you want connected to this module.
Use
Table 34
Note: Use 16 wire pairs from each connector for the DSM 32.
Note: If you are connecting an DSM 16, 4X16, or DSM 32, use
If you are connecting an ASM 8 or GASM8, use the
For an overview of BIX wiring conventions, refer to the Business Communications Manager
BIX Box Wiring Guide.
Install the telephones and peripheral equipment wiring (if new system):
2
Attach the cables for the telephones to the connecting blocks.
a
b Install the telephones. Each telephone comes with hardware installation instructions.
Refer also to
Note: You can configure most types of telephones before they are installed. Refer to the
Programming Operations Guide for specific instructions about telephone settings and
using the New Users Wizard to set up telephones.
To connect analog equipment to a digit line, refer to
c
Terminal Adapters," on page
N0008587 01
and
Figure 57 on page
Chapter 13, "Installing optional telephony equipment," on page
149.
139.
Table 35 on page
Chapter 12, "Installing Analog
Table 34 on page
139.
140.
157.