Mediant 2000 SIP User's Manual
Table 12-1: Mediant 2000 Selected Technical Specifications (continues on pages 183 to 185)
Function
Environmental (AC)
Hot Swap
Enclosure Dimensions
Installation
Type Approvals
Telecommunication
Standards
Safety and EMC Standards
Environmental
Diagnostics
Front panel Status LEDs
Syslog events
SNMP MIBs and Traps
All specifications in this document are subject to change without prior notice.
Version 4.4
Operation Temp:
0° to 40° C / 32° to 104° F
Storage:
-40° to 70° C / -40° to 158° F
Humidity:
10 to 90% non-condensing
cPCI cards are full hot swap supported
Power supplies are redundant but not hot swappable
445 x 44 x 300 mm; 17.5 x 1.75 x 12 inch.
1U 19-inch 2-slot cPCI chassis, Rack mount, shelf or desk top.
Rack mount with 2 side brackets, option 2 extra (rear) side brackets.
IC CS03; FCC part 68
Chassis and Host telecom card are approved to the following telecom standards: IC
CS03; FCC part 68; CTR 4, CTR 12 & CTR 13; JATE; Anatel, Mexico Telecom, Russia
CCC, ASIF S016, ASIF S038.
UL 60 950-1, FCC part 15 Class B, (Class A with Sun 2080 CPU card)
CE Mark (EN 55022 Class B (Class A with Sun 2080 CPU card), EN 60950-1, EN
55024, EN 300 386), TS001
NEBS Level 3: GR-63-Core, GR-1089-Core, Type 1 & 3. Approved for DC powered
version.
Complies with ETS 301019; ETS 300019-1, -2, -3. (T 1.1, T 2.3, T3.2). Approved for
AudioCodes or DC powered versions.
E1/T1 status
LAN status
Gateway status (Fail, ACT, Power, and Swap Ready).
Supported by Syslog Server, per RFC 3164 IETF standard.