acAlarmVarbinds and also in acBoard.acTrap. acBoardTrapDefinitions.
oid_1_3_6_1_4_1_5003_9_10_1_21_2_0).
The table size can be altered via
notificationLogMIB.notificationLogMIBObjects.nlmConfig.nlmConfigGlobalEntryLimit or
notificationLogMIB.notificationLogMIBObjects.nlmConfig.nlmConfigLogTable.nlm
ConfigLogEntry.nlmConfigLogEntryLimit.
The table size can be any value between 50 to 1000 and is 500 by default.
Traps - Full proprietary trap definitions and trap Varbinds are found in the acBoard MIB and
acAlarm MIB.
The following proprietary traps are supported in the device:
acBoardEvResettingBoard - Sent after the device is reset.
acBoardEvBoardStarted - Sent after the device is successfully restored and initialized
following reset.
acBoardTemperatureAlarm - Sent when a board exceeds its temperature limits.
acBoardConfigurationError - Sent when a device's settings are illegal - the trap contains
a message stating/detailing/explaining the illegality of the setting.
acBoardFatalError - Sent whenever a fatal device error occurs.
acFeatureKeyError - Development pending. Intended to relay Feature Key errors, etc.
acgwAdminStateChange - Sent when Graceful Shutdown commences and ends.
acBoardCallResourcesAlarm - Indicates that no free channels are available.
acBoardControllerFailureAlarm - The Gatekeeper/Proxy is not found or registration
failed. Internal routing table can be used for routing.
acBoardEthernetLinkAlarm - Ethernet link or links are down.
acBoardOverloadAlarm - Overload in one or some of the system's components.
acActiveAlarmTableOverflow - An active alarm could not be placed in the active alarm
table because the table is full.
acAtmPortAlarm
acAudioProvisioningAlarm
In addition to the listed traps, the device also supports the following standard traps:
dsx1LineStatusChange
coldStart
authenticationFailure
Note 1:
Note 2:
Additional MIBs are to be supported in future releases.
Mediant 2000 SIP User's Manual
1
- ATM Port Alarm.
1
The following are special notes pertaining to MIBs:
A detailed explanation of each parameter can be viewed in an SNMP browser
in the 'MIB Description' field.
Not all groups in the MIB are functional. Refer to version release notes.
Certain parameters are non-functional. Their MIB status is marked 'obsolete'.
When a parameter is set to a new value via SNMP, the change may affect
device functionality immediately or may require that the device be soft reset for
the change to take effect. This depends on the parameter type.
The current (updated) device configuration parameters are programmed into
the device provided that the user does not load an ini file to the device after
reset. Loading an ini file after reset overrides the updated parameters.
- Raised if the Media Server is unable to provision its audio.