Table 12-1: Mediant 2000 Selected Technical Specifications (continues on pages 183 to 185)
Function
Fax Transparency
Modem Transparency
Protocols
VoIP Signaling Protocol
Communication Protocols
Telephony Protocols
In-Band Signaling
Interfaces
Telephony Interface
Network Interface
LED Indicators
LED Indications on Front
Panel
Connectors & Switches
Rear Panel
Trunks
1 to 8 and 9 to 16
Ethernet 1 and 2
AC Power
DC Power
Physical
AC Power Supply
DC Power Supply (optional) 36 to 72 VDC (nominal 48 VDC), 4A max, floating input
Environmental (DC)
Mediant 2000 SIP User's Manual
Automatic fax bypass (pass-through) to G.711, ADPCM or NSE bypass mode
Automatic switching (pass-through) to PCM, ADPCM or NSE bypass mode for modem
signals (V.34 or V.90 modem detection)
SIP - RFC 3261
RTP/RTCP packetization.
IP stack (UDP, TCP, RTP).
Remote Software load (TFTP & BootP support).
PRI (ETSI Euro ISDN, ANSI NI2, 4/5ESS, DMS 100, QSIG Basic Call, Japan INS1500,
Australian Telecom, New Zealand Telecom, Hong Kong Variant, Korean MIC)
E1/T1 CAS protocols: MFC R2, E&M wink start,
Immediate start, delay start, loop start, ground start,
Feature Group B, D for E1/T1
DTMF (TIA 464A)
MF-R1, MFC R2
User-defined Call Progress Tones
1, 2, 4, 8 or 16 E1/T1/J1 Balanced 120/100 ohm
Two 10/100 Base-TX, half or full duplex with auto-negotiation
Power, ACT/Fail, T1/E1 status, LAN status, Swap ready indication
Two 50-pin female Telco connectors (DDK57AE-40500-21D) or 8 RJ-48c connectors
for trunks 1 to 8 only
Two 10/100 Base-TX, RJ-45 shielded connectors
Standard IEC320 Appliance inlet.
Option for a dual (fully redundant) power supply.
2-pin terminal block (screw connection type) suitable for field wiring
applications connecting DC
Phoenix Contact.
earth
Bonding and
ing: A 6-32-UNC screw is provided. Correct ring terminal and 16
AWG wire minimum must be used for connection.
Or crimp connection shown below.
Note that to meet UL approvals, users must fulfill the criteria below.
2-pin terminal block (crimp connection type)
Shroud:
Adaptor:
Contacts:
Cable requirement:
Universal 90 to 260 VAC 1A max, 47-63 Hz
Option for a dual redundant power supply.
Operation Temp:
Short Term Operation Temp (per NEBS):
Storage:
Humidity:
Specification
connector: MSTB2.5/2-STF (5.08 mm) from
Power
comprising a Phoenix Contact
MSTBC2,5/2-STZF-5,08.
MSTBC-MT0,5-1,0
18 AWG x 1.5 m length.
0° to 40° C / 32° to 104° F
0° to 55° C / 32° to 131° F
-40° to 70° C / -40° to 158° F
10 to 90% non-condensing