Nortel Mediant TP-1610 SIP User Manual page 104

Nortel networks voip media gateway user's manual
Table of Contents

Advertisement

Table 6-3: SIP Configuration Parameters (continues on pages 100 to 110)
ini File Field Name
Web Parameter Name
CoderName
[Coders]
AMRPayloadType
Mediant 2000 SIP User's Manual
*
CoderName = Coder,ptime (can appear up to 5 times)
The following coder names can be selected:
g711Alaw64k
– G.711 A-law.
– G.711 µ-law.
g711Ulaw64k
g7231
– G.723.1 6.3 kbps (default).
g7231r53
– G.723 5.3 kbps.
g726
– G.726 ADPCM 32 kbps (Payload Type = 2).
g729
– G.729A.
NetCoder6_4
– NetCoder 6.4 kbps.
NetCoder7_2
– NetCoder 7.2 kbps.
NetCoder8
– NetCoder 8.0 kbps.
NetCoder8_8
– NetCoder 8.8 kbps.
Transparent
– Transparent coder.
Evrc
– EVRC coder.
Amr
– AMR coder.
Note: The coder name is case-sensitive.
The RTP packetization period (ptime, in msec) depends on the selected Coder name,
and can have the following values:
g711 family
– 10,20,30,40,50,60,80,100,120 (default=20).
g729
– 10,20,30,40,50,60,80,100 (default=20).
g723 family
– 30,60,90,120 (default = 30).
G.726
– 10, 20, 40, 60, 80, 100, 120 (default=20).
NetCoder family
– 20, 40, 60, 80, 100, 120 (default=20).
EVRC
– 20, 40, 60, 80, 100 (default=20).
AMR
– 20 only.
Transparent
- 20, 40, 60, 80, 100, 120 (default=20)
Note 1: If not specified, the ptime gets a default value.
Note 2: Each coder should appear only once.
Note 3: The ptime specifies the maximum packetization time the gateway can receive.
Note 4: G.729B is supported if the coder G.729 is selected and
'EnableSilenceCompression' equals 1 or 2.
Note 5: The selected rate of the AMR coder is set according to the parameter
'AMRSendRate'. The selected rate of the EVRC coder is set according to the
parameter 'EVRCRate'.
Note 6: The AMR coder is enabled only if 'DSPVersionTemplateNumber = 1'. When
this DSP template is selected, the maximum number of channels is 160 instead of 240
(rounded to full E1/T1 trunk capacity 30/24 channels per trunk).
Note 7: The EVRC coder is enabled only if 'DSPVersionTemplateNumber = 2'. When
this DSP template is selected, the maximum number of channels is 120 instead of 240
(rounded to full E1/T1 trunk capacity 30/24 channels per trunk). Note that the value of
the parameter 'EnableRFC2658Interleaving' must be identical on both sides of the call.
For example:
CoderName = g711Alaw64k,20
CoderName = g711Ulaw64k,40
CoderName = g7231,90
Determines the payload type that is used when the selected coder is set to one of the
AMR coder variants.
The valid range is 0 to 120. The default value is 64.
Valid Range and Description
104
Mediant 2000 SIP
Document #: LTRT-72504

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mediant 2000

Table of Contents