Configuring The Pri (Internal) Link Using Unified Manager - Nortel R2MFC Installation And Configuration Manual

Media bay module
Table of Contents

Advertisement

54
Chapter 5 Configuring the R2MFC MBM
5
Select all active B-channels that are provisioned for the corresponding E1 in Configuration >
Resources > Telephony Resources > Provisioned Lines. See
There should be 30 channels, unless a partial E1 service is arranged with the CO.
See
Figure
2.0.
Figure 20 BCM lines configuration for R2MFC MBM

Configuring the PRI (internal) link using Unified Manager

1
Open the Unified Manager. See the Programming guide for the host system for an explanation
of how to use Unified Manager.
2
Click the Configuration button on the Unified Manager main page.
The Unified Manager main display opens.
3
Enter your Unified Manager login credentials.
4
Select the appropriate Bus # under the Resources > Media Bay Modules headings in the
navigation tree.
The Bus # information frame displays. See
layout for an R2MFC MBM configured on Bus 06.
5
Select Trunk module from the Programmed Bus Type drop-down list.
NN40010-300
20, for an example of the screen layout for an R2MFC MBM configured on Bus
Figure
Figure 21 on page 55
for an example of the screen
20.