Figure 15 Trunk wiring overview

Connecting an R2MFC MBM to a service provider

Warning: Electrical shock warning.
The Business Communications Manager R2MFC MBMs have been safety-approved for
installation into BCM base units and expansion units. Both the installer and user are
responsible to ensure that installation of the Business Communications Manager hardware
does not compromise existing Safety approvals.
BEFORE YOU OPEN the Business Communications Manager base unit or Business
Communications Manager expansion unit, ensure that the network telecom cables are
unplugged, and that the unit is then disconnected from the ac power source.
Station modules: The ports on these modules are meant to be connected only to approved
digital telephones and peripherals, with the proper cables, on a protected internal wiring
system.
Do not connect any telephones to wiring that runs outside the building.
Read and follow the installation instructions carefully.
Perform the following steps to connect an R2MFC MBM to the network:
1
Determine the connector type to be used, either RJ48C or BNC connectors.
2
Locate the appropriate connector on the front of the module.
Install R2MCF MBM
Read warnings
Determine the correct
connector to use
R2MFC Media Bay Module Installation and Configuration Guide
Chapter 4 Installing the R2MFC MBM 43
Connect cables to
appropriate trunk
modules
Continue with setup