Pri Side (Internal Link) Configurable Parameters; E1 Framing - Nortel R2MFC Installation And Configuration Manual

Media bay module
Table of Contents

Advertisement

3
Make the required modifications by CLI.
page 73
for an explanation of how to access and navigate the CLI.
Configuration changes made through the CLI immediately affect the operating parameters
in RAM.
Use the SaveCfg - (save configuration permanently on flash) command to save the new
settings on non-volatile Flash memory.
The custom profile remains in EEPROM, even if different country codes are selected with
the DIP switches, and is available again when the "custom profile" DIP switch setting is
selected. The first configuration change by the CLI overwrites the existing custom profile
as described above.
4
Set the Config DIP switches to custom profile. The new custom profile is used upon restart.
See
Figure 18
Figure 18 Custom profile DIP switch setting
6
5
4

PRI side (Internal Link) configurable parameters

The R2MFC MBM is recognized by the BCM as a Euro-ISDN PRI line. The configuration for the
PRI side (internal link) of the link is performed on the BCM through either Element Manager or
Unified Manager. Refer to the Installation and Maintenance guide for the host system for complete
information on the parameters that can be configured through the BCM. PRI side, internal link,
and operational parameters for E1framing and signaling are listed below:

E1 Framing

The list of E1 framing parameters are listed in
Table 4 E1 framing default parameters
Parameter
Frame format
PCM coding
Common Channel Signaling
Note: Only one custom profile exists in EEPROM, so the SaveCfg
command overwrites the previous custom profile saved to the EEPROM.
for the custom profile DIP switch setting.
3
2
1
Operational Value
alternate frame
A-law
TS16
R2MFC Media Bay Module Installation and Configuration Guide
Chapter 5 Configuring the R2MFC MBM
See Chapter 7, "Command Line Interface (CLI)," on
Table
4.
51