ALarm directory
Table 23 includes the CLI commands for alarm configuration and status. The commands are
accessed from the ALarm directory.
Table 23 ALarm directory CLI commands (Sheet 1 of 2)
CLI command
G1Res <link_no> <group I alarms>
Bit3 <link_no> <bit3>
OP16 <link_no> <AIS
TS16
FR <link_no> <fr_mode>
G1th <link_no> <pra> <limcount>
Description
Resets Group 1 alarm counters.
Where:
link_no is the link number, either 0 or 1.
Group I alarms defines the group and can have values of:
•
0 – BPV
•
1 – FBER
•
2 – SLIP
•
3 – CRC4
•
4 – ALL
Used for bit 3 option handling.
Where:
link_no is the link number, 0 or 1.
bit3 is the option flag, 0 (off) or 1 (on).
>
Used for AIS
Where:
link_no is the link number, 0 or 1.
AIS
is the option flag, 0 (off) or 1 (on).
TS16
Changes the frame mode.
Where:
link_no is the PCM link number, 0 or 1.
fr_mode is 0 (ALTRNT2_FRM) or 1 (MULTIFRM_CRC4)
Default for link 0 (external) depends on country selection. Default for link 1
(internal) is set to alternate and should not be changed to multframe.
Sets the group I alarm thresholds.
Where:
link_no is the PCM link number, 0 or 1.
pra is the problem group I errors and can have values of:
•
0 – BPV
•
1 – FBER
•
2 – SLIP
•
3 – CRC4
limcount is the threshold error count in the range of 1...1000.
R2MFC Media Bay Module Installation and Configuration Guide
Chapter 7 Command Line Interface (CLI) 81
option handling.
TS16