Wiring An R2Mfc Mbm - Nortel R2MFC Installation And Configuration Manual

Media bay module
Table of Contents

Advertisement

Figure 13 How to remove the expansion unit front bezel
BCM expansion unit
5
Grasp the top and bottom edges of the R2MFC MBM. Remove the R2MFC MBM from the
BCM expansion unit. Place the R2MFC MBM in a clean, safe, and static-free area.

Wiring an R2MFC MBM

This section describes how to wire the cables that connect to the R2MFC MBM. The R2MFC
MBM is connected to the CO by either RJ48C or BNC connectors. The BNC connector is the
default interface. The default connector can be changed either by setting the country - selection
DIP switches or by creating a custom country code profile through the CLI. See
MFCR2 (external) link" on page 49
If the 75 Ω BNC connector pair is used, two coax cables are required for transmit and receive.
If the 120 Ω RJ-48 connector is used, the cable pinout must be set up as follows:
Figure 14 R2MFC MBM RJ48 wiring array
R2MFC MBM
connector
1. Push against the bottom
2. Pull out from the top
for information on how to change the active interface.
RJ48 jack
R2MFC Media Bay Module Installation and Configuration Guide
Chapter 4 Installing the R2MFC MBM 41
MBM latches
To network
To plug
Receive from
1- Rtip
network
2 - Rring
3 - Rshield
Transmit to network
4-Ttip
5-Tring
6-Tshield