76 Chapter 7 Command Line Interface (CLI)

VIew directory

Table 20 includes the CLI commands to display the setup parameters. The commands are accessed
from the VIew directory.
Table 20 VIew directory CLI commands
CLI command
LNst
ChSt <chan1> <chan2>
ChDt <chan>
ChDtGrp
TT <num>
MR <mfc_link_no> <num>
NN40010-300
Description
Displays the status of both links.
Displays the status of the channels in the given range.
Where:
chan1 is the lower limit of the range.
chan2 is the upper limit of the range.
The values for chan1 and chan2 are 1...15, 17...31.
Prints the channel data.
Where:
chan is the channel number in the range of 1...15, 17...31.
Prints data for a range of channels.
Prints the timer table that contains the timer values in milliseconds.
Where:
num is either 1 (Outgoing timers) or 2 (Incoming timers).
If you do not enter a value for num, all timers are printed.
Displays the MFC/R2 generic parameters for each link.
Where:
mfc_link_no is the value of the MFC link number, either 0 or 1.
num is 0 (R2 signals), 1 (MFC Tx signals), or 2 (MFC Rx signals).
If you do not enter a value for num, all MFC/R2 signals are printed.