Nortel R2MFC Installation And Configuration Manual page 71

Media bay module
Table of Contents

Advertisement

6
Go to step
8
if the BCM is not active and no calls are running. If calls are running, access the
Control directory.
7
Execute the soft disable (LSD), or immediate disable (LID), to disable the links.
8
Enter the load subdirectory.
9
Execute load y command.
10 Wait for the output of the boot monitor.
11 Enter fload to prepare the MBM for the uploading of firmware.
The R2MFC MBM will not respond while it is waiting for a download.
12 Release the COM port by closing the Hyper-terminal session.
13 Run the download programs on the PC through the Start > run menu:
• //file path/Bload1 <load_file>
The program responds: starting rec 0. Hit any key to continue...
14 Press <Enter>. The program starts the download, and shows its progress by displaying the
number of processed records.
When finished, the program prints: Download ended successfully!
15 Verify the version of firmware uploaded by using the
directory of the CLI. See
16 Close the program window.
17 Remove the cable (part number
from the R2MFC MBM.
Tips: Upgrading the firmware does not erase the custom profile, if the custom profile is
saved in EEPROM.
Chapter 7, "Command Line Interface (CLI)"
N0026100)
connecting the RS232 port and the COM port
R2MFC Media Bay Module Installation and Configuration Guide
Chapter 6 R2MFC MBM maintenance
command in the INfo
Fwversion
for details on the CLI.
71

Advertisement

Table of Contents
loading