74 Chapter 7 Command Line Interface (CLI)

Accessing the CLI

The CLI is accessed through the RS-232 port on the faceplate of the R2MFC MBM. The cable that
was shipped with the R2MFC MBM, part number N0026100, is used to connect a computer to the
R2MFC MBM.
Perform the following steps to access the CLI:
1
Use the shipped cable to connect a PC to the RS-232 port on the faceplate of the R2MFC
MBM through COM1.
2
Open a Hyper-terminal session on the PC using the following parameters:
Table 17 Hyper-terminal setup parameters
Parameter
Connect using
Bits per second
Data bits
Parity
Stop Bits
Flow Control
3
Wait for monitor line (flashing cursor) to appear on the terminal session.
4
Switch to appropriate user by using the
and password.
5
Access the desired directory using the directory commands listed in this chapter.
6
Execute any desired commands.
7
Release the COM port by closing the Hyper-terminal session.
8
Remove the cable connecting the PC to the R2MFC MBM.
NN40010-300
Setting
COM 1 or COM 2
19 200
8
None
1
None
command and entering the appropriate username
su