When you are using multiple DME channels, you can also
define positions and angles in either local or global
coordinates. (Local and global coordinates can not be
selected in this version.)
Local coordinates: These are coordinates that are local to
each DME channel.
Global coordinates: These are coordinates that are
common to all DME channels.
If you want to use global coordinates, you must enable
them in the Setup sub menu by setting the Glbl
parameter to On (see page 136).
The positions and rotation angles of images differ
depending on the coordinates in which they are defined. To
adjust parameters in the Position and Rotation sub menus,
select the coordinates by selecting the following sub
menus.
(xxx: "M/E DME" appears when you are operating on a
transition, and "Keyer" appears when you are operating on
a key.)
• xxx L.Source (Local Source) sub menu: Change
positions and angles in source coordinates.
• xxx L.Target (Local Target) sub menu: Change positions
and angles in target coordinates.
134
Customizing DME Effects
Change X coordinate
Change Y coordinate
Change Z coordinate
Changing the position of an image in source coordinates
Change X coordinate
Change Y coordinate
Change Z coordinate
Changing the position of an image in target coordinates