2.4.17 Position of the Side Paper Deck Pickup Roller Releasing Solenoid

Before removing the deck pickup roller releasing solenoid [1] from the support plate,
make mental notes of the positions of the 2 fixing screws [2] of the solenoid with reference
to the index on the support plate. (Or, mark the position of the solenoid on the support plate
with a scriber.)
If you are replacing the solenoid on its own, you must secure it in its initial position.

2.4.18 Fitting the Side Guide Timing Belt of the Manual Feed Tray Assembly

Butt the rack plate [1] of the manual feed tray against section A (open state).
Move the slide volume [2] in the direction of B, and fit the timing belt [3] to the pulley
[4].
COPYRIGHT© 2001 CANON INC.
[2]
F06-204-21
[3]
[1]
[4]
B
[2]
F06-204-22
2000 2000 2000 2000