CHAPTER 2 NEW FUNCTIONS

7.6 Power Save Mode

When the Power Save mode key is pressed in the control panel, the control temperature in
STBY is made lower than normal to reduce power consumption. F02-706-01 shows the se-
quence of operation used in power save mode.
Power save mode
set in user mode
Main heater (H1)
Sub heater (H2)
200V: controlled to 190ºC
208V/230V: controlled to 200ºC
200ºC
195ºC
170ºC
105ºC
2-112
Power Save
key ON
STBY
SLEEP
Temperature control
according to selected save rate
25% save rate
50% save rate
F02-706-01
COPYRIGHT© 2001 CANON INC.
Power Save
200V: 185ºC
key OFF
208V/230V: 195ºC
WMUP
Returns to normal temperature control
when Power Save key is turned OFF
2000 2000 2000 2000
WMUPR omitted
200V: 190ºC
208V/230V: 200ºC
STBY
200V: controlled to 190ºC
208V/230V: controlled to 200ºC
CANON iR105 REV.0 JULY 2001