After stringing the charging
wire of each charging assembly,
check to make sure that the
length of the tension spring is as
follows:
Primary
charging
A=12.0±1mm
assembly
Pre-transfer
charging
A=12.0±1mm
assembly
Transfer
charging
A=12.0±0.5mm
assembly
Separation
charging
A=12.0±0.5mm
assembly
11) Mount the wire cleaner. At this time,
pay attention to the orientation of the
wire cleaner.
12) Wipe the charging wire with lint-free
paper moistened with alcohol.
COPYRIGHT© 2001 CANON INC.
A
2000 2000 2000 2000
CANON iR105 REV.0 JULY 2001
CHAPTER 2 NEW FUNCTIONS
2-77