4) Remove the E-ring [1], and detach the
pressure plate [2] to detach the cleaning
blade assembly [3].
The pressure plate looks like the
one used for the GP600 Sires or
iR8500 Series machines; how-
ever, it is a different part with a
different parts number. Do not
use the wrong part.
5) Remove the 5 screws [1], and detach the
blade retaining plate [2] to detach the
cleaning blade [3].
c. Mounting the Cleaning Blade
See Chapter 5.
d. Removing the Blade Vibrating Unit
1) Remove the blade unit.
2) Disconnect the connector [1], and re-
move the 2 screws [2]; then, detach the
blade vibrating unit [3].
(The rear and front blade vibrating units
may be disassembled in the same way.)
COPYRIGHT© 2001 CANON INC.
2000 2000 2000 2000
CANON iR105 REV.0 JULY 2001
CHAPTER 2 NEW FUNCTIONS
[1]
[2]
F02-508-13
[1]
[3]
[2]
F02-508-14
[3]
[1]
F02-508-15
[3]
[2]