CHAPTER 2 NEW FUNCTIONS
b. Mounting the Process Unit
Keep the following in mind when mount-
ing the process unit [1] to the slide rail:
1) Be sure to match the notch [2] found at
the tip of the left slide rail against the
front plate [3] of the process unit.
2) Be sure to match the bend [4] at the
front of the right slide rail against the
front plate [3] of the process unit.
Waste toner can drop on the du-
plex unit when the process unit
is removed. After mounting the
process unit. be sure to slide out
the duplex unit and remove the
waste toner.
2-68