Canon iR105 Service Manual page 700

Hide thumbs Also See for iR105:
Table of Contents

Advertisement

E204
Main cause
The scanner motor (M5) is faulty. The image leading edge sensor (PS3) is
faulty. The ADF controller PCB is faulty. The reader controller PCB is
faulty.
Condition
0000 During forward movement in fixed reading mode or during a home
Caution
No code will be indicated. The keys will be locked. You can check the code
in service mode (COPIER>DISPLAY>ERR).
E211
Main cause
The thermistor (TH3) inside the fluorescent lamp heater is faulty. The light
adjustment control PCB is faulty. The reader controller PCB is faulty. The
wiring is faulty (short circuit, open circuit.
Condition
0000 While the power is ON, the ambient temperature of the fluorescent
E215
Main cause
The thermistor (TH3) inside the fluorescent heater has a short circuit. The
light adjustment control circuit is faulty. The reader controller PCB is
faulty. The wiring is faulty (short circuit, open circuit).
Condition
0000 While the fluorescent lamp is OFF, the reading of the ambient tem-
E218
Main cause
The fluorescent lamp is not mounted properly.
Condition
0000 When the power is turned on, the absence of the fluorescent lamp
COPYRIGHT© 2001 CANON INC.
position search, the image leading signal does not occur; or, in
stream reading mode, the image leading edge signal does not arrive
from the ADF controller PCB.
lamp does not exceed 10°C 2 min after the florescent heater has
gone ON; or, after the power is turned on, the reading of the ambi-
ent temperature of the fluorescent lamp is 0°C or lower.
perature is 170°C or higher.
is detected.
2000 2000 2000 2000
CANON iR105 REV.0 JULY 2001
ERROR CODE
E-9