Table 4: Wake Up From Sleep Mode - Siemens MC35 Migration Manual

Cellular engine
Hide thumbs Also See for MC35:
Table of Contents

Advertisement

Migration from MC35 to MC35i
P R E L I M I N A R Y
The table below shows which conditions will wake up MC35 and MC35i from sleep mode
As shown in the following table, MC35i supports two additional sleep modes (7 and 8).

Table 4: Wake up from SLEEP mode

Event
Ignition line
/RTS0 or /RTS1 (falling edge)
Unsolicited Result Code
(URC)
Incoming voice or data call
Any AT command (incl. outgoing
voice or data call, outgoing SMS)
Incoming SMS depending on
mode selected by AT+CNMI:
AT+CNMI=0,0 (= default, no
indication of received SMS)
AT+CNMI=1,1 (= displays
URC upon receipt of SMS)
GPRS data transfer
RTC alarm
AT+CFUN=1
Migration from MC35 to MC35i
AT+CFUN=0 Þ
AT+CFUN=1
MC35
MC35i
No
Yes
Yes
Yes
Not Possible (UART
disabled)
No
Yes
Not Possible (UART
disabled)
Yes
Not Possible (UART
disabled)
11 of 30
AT+CFUN=5 or 6 Þ
AT+CFUN=1
MC35
MC35i
No
No
Yes
Yes
No
No
Yes
No
Yes
Yes
AT+CFUN=7 or 8 Þ
AT+CFUN=1
MC35i only
MC35 does not support
sleep modes 7 and 8
MC35i
No
No
No
No
No
No
No
No
No
Yes
12.03.03