Table 12: At Commands From Gsm 07.07 - Siemens MC35 Migration Manual

Cellular engine
Hide thumbs Also See for MC35:
Table of Contents

Advertisement

Migration from MC35 to MC35i
P R E L I M I N A R Y
AT commands originating from GSM 07.07
5.2.3

Table 12: AT commands from GSM 07.07

#
AT
73 AT+CACM
Accumulated call meter (ACM) reset or query
74 AT+CALA
Set alarm time
75 AT+CAMM
Accumulated call meter maximum (ACMmax) set or query
76 AT+CAOC
Advice of Charge information
77 AT+CBST
Select bearer service type
78 AT+CCFC
Call forwarding number and conditions control
79 AT+CCLK
Real Time Clock
80 AT+CCUG
Closed User Group
81 AT+CCWA
Call waiting
82 AT+CEER
Extended error report
83 AT+CFUN
Set phone functionality
Additional parameters and notes
MC35
Two additional CYCLIC SLEEP modes:
N/A
Note:
If SLEEP mode (<fun>=0, 5, or 6) is activated while
a circuit-switched call is in progress, this call will
immediately be terminated.
84 AT+CGMI
Request manufacturer identification
85 AT+CGMM
Request model identification
Differing result codes
MC35
MC35
OK
86 AT+CGMR
Request revision identification of software status
87 AT+CGSN
Request product serial number identification (IMEI) identical to GSN
88 AT+CHLD
Call hold and multiparty
89 AT+CHUP
Hang up call
90 AT+CIMI
Request international mobile subscriber identity
91 AT+CIND
Indicator control
Differing parameter implementation
MC35
N/A
92 AT+CLCC
List current calls of ME
Differing parameter implementation
Migration from MC35 to MC35i
Command
MC35i
Two additional CYCLIC SLEEP modes available:
7 CYCLIC SLEEP mode:
In this mode, the serial interface is shortly enabled
during paging. If characters are recognized on the
serial interface,
the ME stays active for 2 seconds after the last
character was sent or received.
ME exits SLEEP mode only if AT+CFUN=1 is
entered.
8 CYCLIC SLEEP mode:
In this mode, the serial interface is shortly enabled
during paging. If characters are recognized on the
serial interface,
the ME stays active for 10 minutes after the last
character was sent or received.
ME exits SLEEP mode only if AT+CFUN=1 is
entered.
Note:
When a circuit-switched call is in progress, <fun>=7
or 8 can be activated without terminating the call.
However, setting <fun>=0, 5 or 6 during a circuit-
switched call immediately disconnects this call.
MC35i
MC35i
OK
MC35i
Additional "rssi" value available for <desc>
parameter:
Received signal (field) strength, scaled to value
range 0...5, or 99 if not measurable.
0: signal strength < 112 dBm
1 - 4: signal strength in 15 dBm steps
5: signal strength > -51 dBm
See also AT+CSQ in Chapter 4.46. Value range of
AT+CSQ is 0 - 31.
23 of 30