f. Toner reception seal
1) Remove the drum unit.
2) Remove the drum.
3) Remove the screw, and remove the toner reception seal.
Note: Do not deform the seal.
g. MC cleaner
1) Remove the drum unit.
2) Remove the screw, and remove cover (A).
3) Remove the MC unit.
4) Release the pawl, and remove the MC case upper in the arrow
direction.
5) Release the pawl, and remove the MC case lower in the arrow
direction.
6) Remove the screen grid.
7) Disengage the pawl, and remove the MC cleaner.
AR-BC260 DESCRIPTIONS OF EACH SECTION 7 - 21
h. LED unit removal
1) Remove the rear cabinet.
2) Remove the PCU PWB unit.
3) Remove the developing unit.
4) Remove the drum unit.
5) Remove the top cover, and disconnect the connector of the
ICU.
Y
M
C
K
6) Remove the screw (A) on the rear side, and remove the LED
unit.
A
A
7) Remove the LED unit.
8) Remove the connector cover and the harness.