Sharp AR-BC260 Service Manual page 180

Digital full color multifunctional system
Hide thumbs Also See for AR-BC260:
Table of Contents

Advertisement

44
-4
Purpose
Setting
Function
Image forming section correction, image density
(Purpose)
sensor adjustment conditions setup
Section
Process (Photoconductor, development, transfer)
Item
Picture quality
Operation/
1. Select the item to beg set by the scroll key.
Procedure
2. Enter the set value with the 10-key, and press
the [OK] key. (The entered value is set.)
Set all to the default values.
(Display items)
Display
Content
A PCS_C TARGET
Color image density
sensor adjustment target
value
B PCS_K TARGET
Black image density
sensor adjustment target
value
C LED_C OUTPUT
Initial current level in
color image density
sensor adjustment
D LED_K OUTPUT
Initial current level in
black image density
sensor adjustment
E PCS ADJSTMENT
Allowable error level in
LIMIT
adjustments
F
BELT GROUND
Error judgment level for
DIF
the belt surface detection
level difference
G BIAS_CL
Set value (color) of the
STANDARD DIF
developing basis
correction start voltage
difference in high density
image correction
H BIAS_BK
Set value (black) of the
STANDARD DIF
developing basis
correction start voltage
difference in high density
image correction
I
BIAS PATCH
Patch forming developing
INTERVAL
bias voltage interval
(voltage difference) in
high density image
correction
J
Y_PAT TARGET
Base target density level
ID
(Y) in high density image
correction
K M_PAT TARGET
Base target density level
ID
(M) in high density image
correction
L
C_PAT TARGET
Base target density level
ID
(C) in high density image
correction
M K_PAT TARGET
Base target density level
ID
(K) in high density image
correction
N HV BK_GROUND
Error judgment level for
LIMIT
belt surface detection
level difference
(Allowable range of
transfer belt surface
detection level difference
(mix. - min.) of black
toner image patch
position)
O PCS_C MARKET
Adjustment target value
TARGET
(Color image density
sensor) when adjusting
the primary LED current
value by using the
calibration plate in
SIM44-36.
P PCS_C MARKET
LED-REV
Min
Max
Default
Value
Value
value
1
255
108
1
255
201
1
255
51
44
1
255
51
Purpose
Function
(Purpose)
1
255
2
Section
1
255
255
Item
0
255
50
Operation/
Procedure
2. If the operation is normally completed, COMPLETE is
displayed and the correction result becomes valid.
0
255
75
If the operation is not normally completed, ERROPR is highlighted
and the detail of the trouble is displayed.
The detail of correction can be checked with SIM 44-9 and SIM
44-12.
1
255
50
(Result/Detail messages list)
Result display
COMPLETE
ERROR
1
255
108
COMPULSORY
1
255
125
INTERRUPTION
1
255
109
COLOR_SENSOR_
ADJUSTMENT_ERROR
BLACK_GAIN_
1
255
22
ADJUSTMENT_ERROR
BLACK_SENSOR_
1
255
29
ADJUSTMENT_ERROR
BLACK_PROCON_ERROR
CYAN_PROCON_ERROR
MAGENTA_PROCON_ERROR
1
255
110
YELLOW_PROCON_ERROR
CONNECTION_ERROR
AR-BC260 SIMULATION 9 - 42
Display
Content
In SIM44-36, the toner
patch density is read by
three kinds of LED
currents with the primary
LED current adjustment
value as the center value
in order to obtain PCS C
LED ADJ value. This is
the deflection range of
the current value in the
above case. (Color image
density sensor)
-6
Operation test/check
Used to forcibly execute the image forming section
correction (high density process correction) (process
correction).
Process (Photoconductor, developing, transfer,
cleaning)
Operation
1. Press the [EXECUTE] key, and the image
forming section correction is started.
Correction is normally completed.
An error occurred during correction.
(The previous correction result is
maintained.)
Compulsory interruption
Error display
Color image density sensor
adjustment error
Black image density sensor
gain adjustment error
Black image density sensor
adjustment error
High-density image density
correction (process
correction) error (K)
High-density image density
correction (process
correction) error (C)
High-density image density
correction (process
correction) error (M)
High-density image density
correction (process
correction) error (Y)
Sensor-PCU PWB
communication trouble
Min
Max
Default
Value
Value
value
1
255
10
Content
Content

Advertisement

Table of Contents
loading

Table of Contents