(2) Maintenance parts replacement procedure
a. Fusing unit removal
1) Open the left cabinet.
2) Loosen the roller knob (A) and remove the fusing unit (B).
B
b. Upper thermistor
1) Remove the fusing until from the machine.
2) Remove the screw and the harness cover (A).
3) Remove the connector, the screw, and the harness, and
remove the thermistor (B).
A
A
B
AR-BC260 DESCRIPTIONS OF EACH SECTION 7 - 4
c. Lower thermistor
1) Remove the fusing unit from the machine.
2) Remove the screws, and remove the fusing front PG (A).
3) Remove the connector, the screw, and the harness, and
remove the thermistor (B).
d. Upper heater lamp
1) Remove the fusing unit from the machine.
2) Remove the screw and remove the fusing front cover (A).
Remove the harness cover (B).
3) Remove the connector, the screw, and the lamp holder (C),
and remove the upper heater lamp (D).
C
A
e. Lower heater lamp
1) Remove the fusing unit from the machine.
2) Remove the screw, and remove the fusing front cover (A).
3) Remove the screw, and remove the fusing front PG (B).
4) Remove the connector, the screw, and the lamp holder (C),
and remove the lower heater lamp (D).
A
C
B