Sharp AR-BC260 Service Manual page 157

Digital full color multifunctional system
Hide thumbs Also See for AR-BC260:
Table of Contents

Advertisement

8
-2
Purpose
Adjustment/Operation test/check
Function
Used to check and adjust the operation of each print
(Purpose)
mode main charger grid voltage and the control
circuit.
Section
Process
(Photoconductor, developing, transfer, cleaning)
Operation/
(The charging/grid output voltage in each print mode
Procedure
can be adjusted and checked.)
1. Select the color mode with the [K], [C], [M], and
[Y] keys.
When [EXECUTE] key is pressed, the display is
highlighted and the currently set voltage is
outputted.
(Set value)
Color
Item
K
A: HIGH SPEED
High speed (117mm/s) (B & W)
B: MIDDLE SPEED
Middle speed (78mm/s) (Color) (B & W)
C: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W)
(Special paper)
C
A: MIDDLE SPEED
Middle speed (78mm/s) (Color) (B & W)
B: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W)
(Special paper)
M
A: MIDDLE SPEED
Middle speed (78mm/s) (Color) (B & W)
B: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W)
(Special paper)
Y
A: MIDDLE SPEED
Middle speed (78mm/s) (Color) (B & W)
B: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W)
(Special paper)
8
-6
Purpose
Adjustment/Operation test/check
Function
Used to check and adjust the operation of the
(Purpose)
transfer charger current and the control circuit.
Section
Process (Photoconductor, developing,
transfer, cleaning)
Operation/
1. Select the color mode with the [K], [C], [M], and
Procedure
[Y] keys.
2. Select the copy mode with the scroll key.
3. Enter the adjustment value with the 10-key pad.
4. Press the [EXECUTE] key.
Operation mode
Adjustment
range
180 – 700
180 – 700
180 – 700
180 – 700
180 – 700
180 – 700
180 – 700
180 – 700
180 – 700
Transfer
AR-BC260 SIMULATION 9 - 19
2. Select the print mode with [
3. Enter the adjustment value with the 10-key pad.
4. Press the [EXECUTE] key.
The [EXECUTE] key is highlighted, the adjustment value entered
in procedure 2 is set, and the voltage corresponding to the set
value is outputted.
The voltage is supplied for 30 sec, then the [EXECUTE] key
returns to the normal display.
If the [EXECUTE] key is pressed while the voltage is supplied, the
voltage output is stopped and the [EXECUTE] key returns to the
normal display.
Adjustment value
Monitor (High voltage PWB)
Specified
Monitor voltage
value (Default)
(Specified value)
620
53.5 ± 0.2v
620
53.5 ± 0.2v
620
53.5 ± 0.2v
620
53.5 ± 0.2v
620
53.5 ± 0.2v
620
53.5 ± 0.2v
620
53.5 ± 0.2v
620
53.5 ± 0.2v
620
53.5 ± 0.2v
The [EXECUTE] key is highlighted, the adjustment value entered
in procedure 2 is set, and the voltage corresponding to the set
value is outputted.
The voltage is supplied for 30 sec, then the [EXECUTE] key
returns to the normal display.
If the [EXECUTE] key is pressed while the voltage is supplied, the
voltage output is stopped and the [EXECUTE] key returns to the
normal display.
In this simulation, when the transfer voltage is supplied, the
transfer belt and the OPC drum rotates at the same time.
Therefore, the above parts are not damaged.
] key and [
] key.
Main charger grid voltage
Pin
Actual
No.
voltage
Connector
CNMONK
1
–620v
CNMONK
1
–620v
CNMONK
1
–620v
CNMON
3
–620v
CNMON
3
–620v
CNMON
7
–620v
CNMON
7
–620v
CNMON
11
–620v
CNMON
11
–620v

Advertisement