Sharp AR-BC260 Service Manual page 178

Digital full color multifunctional system
Hide thumbs Also See for AR-BC260:
Table of Contents

Advertisement

41
-3
Purpose
Operation test/check
Function
Used to check the operation of the document size
(Purpose)
sensor and the related circuit. (The document size
sensor output level can be monitored with the LCD
display.) Current sensor (A/D) value
Section
Others
Item
Operation
Operation/
The detection output level of each sensor (PD1 ~
Procedure
PD7) is displayed in real time.
The value in [ ] shown at the right of each sensor name is the
threshold value.
PD1 – PD7 light receiving (A/D value) and threshold value (A/D
value) range is 1 – 255. The default of the threshold value is 128.
43
43
-1
Purpose
Setting
Function
Used to set the fusing temperature in each operation
(Purpose)
mode.
Section
Fixing (Fusing)
Item
Operation
Operation/
1. Select the kind of lamps and the operation mode
Procedure
with the scroll key.
2. Enter the set value with the 10-key.
3. Press the [OK] key to set the fusing temperature set in
procedure 2.
(Display items)
Display
Content
A
TH1 ready standby
70 – 230
B
TH2 ready standby
30 – 200
C
TH1 BW normal paper
70 – 230
duplex mode
D
TH2 BW normal paper
30 – 200
duplex mode
E
TH1 color normal paper
70 – 230
duplex mode
F
TH2 color normal paper
30 – 200
duplex mode
G
Fusing motor forward
30 – 200
rotation start TH12
temperature
H
Fusing motor forward
30 – 200
rotation end TH2
temperature
I
Warm-up completion
90 – 255
time
J
TH1 heavy paper
70 – 230
K
TH2 heavy paper
30 – 200
L
TH1 heavy paper 2
70 – 230
M
TH2 heavy paper 2
30 – 200
N
TH1 OHP1
70 – 230
O
TH2 OHP1
30 – 200
P
TH1 OHP2
70 – 230
Q
TH2 OHP2
30 – 200
R
TH1 envelope
70 – 230
S
TH2 envelope
30 – 200
T
TH1 preheating
30 – 200
U
Reset from TH1
30 – 200
preheating
Default
Set
100v
120v
200v
China
range
Series
Series
Series
only
150
150
150
150
135
135
135
135
160
160
160
160
145
145
145
145
145
145
145
145
135
135
135
135
135
135
135
135
135
135
135
135
90
90
90
90
170
170
170
170
135
135
135
135
175
175
175
175
145
145
145
145
170
170
170
170
155
155
155
155
170
170
170
170
155
155
155
155
180
180
180
180
145
145
145
145
138
138
138
138
160
160
160
160
AR-BC260 SIMULATION 9 - 40
43
-4
Purpose
Setting
Function
Used to set the fusing temperature for each paper.
(Purpose)
Section
Fixing (Fusing)
Item
Operation
Operation/
1. Select the paper kind and the operation mode
Procedure
with the scroll key.
2. Enter the set value with the 10-key.
3. Press the [OK] key to set the fusing temperature
set in procedure 2.
(Display items)
Display
Content
A
TH1 BW normal paper
70 – 230
duplex mode
B
TH2 BW normal paper
30 – 200
duplex mode
C
Applicable number of
sheets in BW normal
paper duplex mode
D
TH1 color normal paper
70 – 230
duplex mode
E
TH2 color normal paper
30 – 200
duplex mode
F
Applicable number of
sheets in color normal
paper duplex mode
G
TH1 BW heavy paper
70 – 230
duplex mode
H
TH2 BW heavy paper
30 – 200
duplex mode
E
Applicable number of
sheets in BW heavy
paper duplex mode
F
TH1 color heavy paper
70 – 230
duplex mode
G
TH2 color heavy paper
30 – 200
duplex mode
H
Applicable number of
sheets of color heavy
paper duplex mode
I
LL environment
temperature set value
J
HH environment
temperature set value
Default
Set
100v
120v
200v
China
range
Series
Series
Series
only
155
155
155
155
100
100
100
100
0 – 60
0
0
0
0
150
150
150
150
100
100
100
100
0 – 60
0
0
0
0
165
165
165
165
100
100
100
100
0 – 60
0
0
0
0
165
165
165
165
100
100
100
100
0 – 60
0
0
0
0
0 – 99
18
18
18
18
0 – 99
30
30
30
30

Advertisement

Table of Contents
loading

Table of Contents