Sharp AR-BC260 Service Manual page 48

Digital full color multifunctional system
Hide thumbs Also See for AR-BC260:
Table of Contents

Advertisement

(2) Maintenance parts replacement procedure
a. Transfer unit removal
1) Open the left cabinet, and remove the fusing unit. (Refer to the
section of the fusing unit.)
2) Hold section A of the transfer unit and pull it in the arrow direc-
tion so that you can hold both sides of the unit.
3) Hold both sides B and remove the transfer unit from the
machine.
A
Note: Be careful not to scratch the surface of the transfer belt.
B
A
b. Belt drive motor
1) Remove the transfer unit from the machine.
2) Remove the screw, and remove the belt cover gear.
3) Remove the connector, the screw, and the motor.
B
B
A
AR-BC260 DESCRIPTIONS OF EACH SECTION 7 - 11
c. Process control sensor
1) Remove the transfer unit from the machine.
2) Remove the connector and the screw, and remove the belt
drive unit.
3) Remove the spring from the hook section.
4) Remove the hook, and remove the process control shutter.
Cleaning: Clean the calibration sheet. (Wipe with soft, dry
cloth.)
5) Remove the connector and the screws, and remove the pro-
cess control sensor.

Advertisement

Table of Contents
loading

Table of Contents