Pcu Pwb Error; Details - Sharp AR-BC260 Service Manual

Digital full color multifunctional system
Hide thumbs Also See for AR-BC260:
Table of Contents

Advertisement

Main
Sub
code
code
L3
00
Mirror return trouble
L4
02
Paper feed motor lock trouble
06
07
11
L8
01
Full wave signal not provided
02
04
00
U0
00
ICU-OPE communication trouble (ICU/OPE
detection)
U1
01
FAX battery abnormality
02
U2
00
EEPROM read/write error (ICU detection)
11
22
30
80
81
90
91
02
U6
00
Desk communication trouble
01
02
03
09
LCC lift motor trouble
10
Desk transport motor trouble
20
LCC communication trouble
21
LCC transport motor trouble
22
LCC 24V power abnormality
50
Desk incompatibility trouble
51
LCC incompatibility trouble
U7
00
RIC communication trouble
UC
02
CPT-ASIC trouble (MFP PWB trouble)

6. Details

Main
Sub
Title

PCU PWB error

code
code
A0
00
Display
Lamp/Message
Phenomenon Detail
Section PCU PWB
Case 1
Cause
Check &
Remedy
Case 2
Cause
Check &
Remedy
Content
When the power is turned
on, conformity of the PCU
PWB and the PCU ROM is
checked to be found that
there is no conformity.
PCU PWB trouble
Replace the PCU PWB.
PCU PWB mistaken
Replace the PCU PWB.
AR-BC260 TROUBLESHOOTING 11 - 3
Main
Sub
Title
Transfer charger trouble (Black)
code
code
C2
10
Display
Lamp/Message
Phenomenon Detail
Section Transfer
Cause
Check &
Remedy
Cause
Check &
Remedy
Cause
Check &
Remedy
Cause
Check &
Remedy
Cause
Check &
Remedy
Image data memory trouble
code
code
E7
01
Display
Lamp/Message
Phenomenon Detail
Section ICU PWB
Case 1
Cause
Check &
Remedy
Case 2
Cause
Check &
Remedy
Case 3
Cause
Check &
Remedy
The difference between the
belt surface output and the
K-color patch density output
does not reach the specified
level. (Judged when
installing a new developing
unit.)
TC-K output abnormality
TC-K analog input/output
abnormality.
Replace the TC PWB.
MC output abnormality
Replace the MC PWB.
Transfer unit trouble
Replace the transfer unit.
PCU PWB trouble
Replace the PCU PWB.
Connector, harness trouble
(PCU PWB, TC PWB, MC
PWB, transfer unit)
Check contact. Replace the
harness. Replace the PWB.
The ICU image data
memory (SDRAM) cannot
be detected as 256MB or
more. The required SDRAM
capacity for the model is not
provided.
The SDRAM of ICU PWB is
not installed. The SDRAM
of ICU PWB is improperly
installed.
Check installation of the
SDRAM of ICU ASIC PWB.
The SDRAM of ICU PWB
does not operate properly.
Use SIM 22-10 to check the
capacity of the SDRAM.
Replace the SDRAM of ICU
PWB.
ICU PWB abnormality
Replace the ICU PWB.

Advertisement

Table of Contents
loading

Table of Contents