3.
Disconnect the sensor cable (A), and remove the assembly.

MPF wear strips removal

See
"Left and rear covers" on page 7-5
1.
Open the left access door assembly.
2.
Insert a flat-blade screwdriver behind the top of the strip, and then twist the screwdriver to pop out the strip.

Operator panel (OP) assembly removal

1.
Remove the top cap cover. See
Note: If you have any output options installed, then the top cap cover is already removed. Remove the
output options and HTU redrive unit instead.
2.
Remove the OP panel bezel. See
A
for the part numbers.
"Top cap cover removal" on page
"OP panel bezel removal" on page
4-27.
4-17.