Sensor (Input, S1, Narrow Media, Near Narrow Media) Removal - Lexmark C792e 5062-210 Service Manual

C792 series
Hide thumbs Also See for C792e 5062-210:
Table of Contents

Advertisement

5.
Disconnect the cable to remove the sensor.
Installation note: Place the plastic clip in the notch in the duplex unit before you reattach the rail cover.

Sensor (input, S1, narrow media, near narrow media) removal

See
"Left" on page 7-10
1.
Remove the staging deflector assembly. See
2.
Locate the sensor you need to replace: input (A), S1 (B), narrow media (C), near narrow media (D).
for the part number.
"Staging deflector assembly removal" on page
5062
4-135.