938.19-Waste Toner Full Sensor Error Service Check - Lexmark C792e 5062-210 Service Manual

C792 series
Hide thumbs Also See for C792e 5062-210:
Table of Contents

Advertisement

938.19—Waste toner full sensor error service check
Step
Questions / actions
1
Turn the printer off, and open the system
board shield. Check the cable in connector
JWTBF1 for proper connection to the system
board.
Is the cable properly connected?
2
Check the cable for damage.
Is the cable damaged?
3
Remove the waste toner full sensor. See
"Waste toner full sensor removal" on
page
4-151.
Check the cable connected to the sensor.
Is the cable properly connected?
4
Replace the waste toner full sensor. See
"Waste toner full sensor removal" on
page
4-151.
Does the error reoccur?
Yes
Go to step 2.
Replace the waste toner
cable. See
"Waste toner
full cable removal" on
page
4-150.
Go to step 4.
Replace the system board.
See
"System board
removal" on page
4-142.
No
Reseat the cable.
Go to step 3.
Reseat the cable.
Problem solved.
2-105
Diagnostic information
5062

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C792dte 5062-230C792de 5062-230C792dhe 5062-235

Table of Contents