The following example shows that "0" was returned as the end status since the
execution of the deleteboard command completed successfully.
XSCF>   showresult
0
8.
Execute the showboards command to confirm that the chassis requiring
maintenance has been released from the physical partition.
In the following example, the [Pwr], [Conn], and [Conf] columns all display "n"
for PSB 00-0, indicating that PSB 00-0 has been released.
XSCF>   showboards -a
PSB     PPAR-ID(LSB)   Assignment     Pwr     Conn   Conf   Test         Fault
----   ------------   -----------   ----   ----   ----   -------   --------
00-0   00(00)               Assigned         n         n         n         Passed     Degraded
01-0   00(01)               Assigned         y         y         y         Passed     Normal
02-0   00(02)               Assigned         y         y         y         Passed     Normal
03-0   00(03)               Assigned         y         y         y         Passed     Normal
9.
Execute the ldm list-domain command from the control domain console of the
physical partition to check for any change in the operating condition of the
logical domain after the deletion of the system board.
5.5
Powering Off the Physical Partition
Requiring Maintenance
This section describes the procedure for powering off the physical partition requiring
maintenance. This applies if the system has a building block configuration and is
operating in multiple physical partitions.
Note - Before stopping the system, inform the users that the system will be stopped.
Note - When a physical partition is stopped by the operation of the XSCF command or the
operation panel, all the logical domains on the physical partition are stopped. Stop
applications as required.
1.
Log in to the XSCF shell.
2.
When the chassis requiring maintenance is operating as the master chassis,
execute the switchscf command to switch the master XSCF to a standby
XSCF.
Enter "y" in response to the confirmation message.
If the chassis requiring maintenance is the slave XSCF, go to step 4.
Chapter 5 Preparations Required for Maintenance
71