Checking the status of a PCI expansion unit
If a PCI expansion unit is connected, execute the ioxadm command from the XSCF
shell to check the status of the PCI expansion unit.
- ioxadm command
Execute the ioxadm command to check the environmental conditions (temperature,
voltage, etc.) or LED indications for the PCI expansion unit.
1.
Log in to the XSCF shell.
2.
Execute the ioxadm command to check the environmental conditions of the
specified PCI expansion unit.
To specify a PCI expansion unit, enter the serial number of the PCI expansion
unit after determining it by executing the ioxadm list command.
The following example shows the environmental conditions for the
PCIBOX#2008 "2008" are the last four digits of the serial number of the PCI
expansion unit.
XSCF>   ioxadm env -te PCIBOX#2008
Location                                           Sensor                           Value   Resolution   Units
PCIBOX#2008                                     AIRFLOW                     180.000             0.000   CHM
PCIBOX#2008                                     P_CONSUMPTION           68.000             0.000   W
PCIBOX#2008/PSU#0                         FAN                           3936.000             0.000   RPM
PCIBOX#2008/PSU#1                         FAN                           3584.000             0.000   RPM
PCIBOX#2008/FAN#0                         FAN                           3374.000             0.000   RPM
PCIBOX#2008/FAN#1                         FAN                           3374.000             0.000   RPM
PCIBOX#2008/FAN#2                         FAN                           3374.000             0.000   RPM
PCIBOX#2008/IOBT                           T_INTAKE                     26.000             0.000   C
PCIBOX#2008/IOBT                           T_PART_NO0                 31.500             0.000   C
PCIBOX#2008/IOBT                           T_PART_NO1                 30.750             0.000   C
PCIBOX#2008/IOBT                           T_PART_NO2                 31.500             0.000   C
PCIBOX#2008/IOBT                           V_12_0V                       12.069             0.000   V
PCIBOX#2008/IOBT                           V_3_3_NO0                     3.293             0.000   V
PCIBOX#2008/IOBT                           V_3_3_NO1                     3.295             0.000   V
PCIBOX#2008/IOBT                           V_3_3_NO2                     3.291             0.000   V
PCIBOX#2008/IOBT                           V_3_3_NO3                     3.300             0.000   V
PCIBOX#2008/IOBT                           V_1_8V                           1.804             0.000   V
PCIBOX#2008/IOBT                           V_0_9V                           0.900             0.000   V
Checking log information
Execute the showlogs command to check error log information.
1.
Log in to the XSCF shell.
2.
Execute the showlogs command to check the log information.
The log information is listed in the order of date, with the oldest appearing first.
The following example shows that an Alarm status occurred in PSU#1 and
PSU#2 at 12:45:31 on Oct 20, the Alarm status changed to a Warning status at
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ November 2014
44