XSCF>   poweroff -a
PPAR-IDs   to   power   off:00,01,02
Continue?   [y|n]   : y
00   :   Powering   off
01   :   Powering   off
02   :   Powering   off
The following processes are performed.
- Oracle Solaris is completely shut down.
- The system stops and enters the POWERON READY state (The XSCF is running).
Note - The order in which guest domains shut down depends on the shut-down group
setting of Oracle VM Server for SPARC.
4.
Check that the POWER LED on the operation panel is off.
Note - For a building block configuration, check the POWER LEDs on all the chassis that
make up the system.
5.
Execute the showpparstatus command to confirm that the power to the
physical partition is turned off.
In the following example, [PPAR Status] displays "Powered Off" for PPAR-IDs
00, 01, and 02, indicating that the power to all the physical partitions has been
turned off.
XSCF>   showpparstatus -a
PPAR-ID   PPAR   Status
00   Powered   Off
01   Powered   Off
02   Powered   Off  
6.
Execute the showdomainstatus command to check the operating condition of
the logical domain.
In the following example, [Status] displays "Solaris powering down" for the
logical domains, indicating that Oracle Solaris is shutting down.
XSCF>   showdomainstatus -p 0
Logical   Domain   Name   Status
primary   Solaris   powering   down
4S-159-D0-G0   Solaris   powering   down
4S-159-D0-G1   Solaris   powering   down
4S-159-D0-G2   Solaris   powering   down  