XSCF> poweroff -a
PPAR-IDs to power off:00,01,02
Continue? [y|n] : y
00 : Powering off
01 : Powering off
02 : Powering off
The following processes are performed.
- Oracle Solaris is completely shut down.
- The system stops and enters the POWERON READY state (The XSCF is running).
Note - The order in which guest domains shut down depends on the shut-down group
setting of Oracle VM Server for SPARC.
4.
Check that the POWER LED on the operation panel is off.
Note - For a building block configuration, check the POWER LEDs on all the chassis that
make up the system.
5.
Execute the showpparstatus command to confirm that the power to the
physical partition is turned off.
In the following example, [PPAR Status] displays "Powered Off" for PPAR-IDs
00, 01, and 02, indicating that the power to all the physical partitions has been
turned off.
XSCF> showpparstatus -a
PPAR-ID PPAR Status
00 Powered Off
01 Powered Off
02 Powered Off
6.
Execute the showdomainstatus command to check the operating condition of
the logical domain.
In the following example, [Status] displays "Solaris powering down" for the
logical domains, indicating that Oracle Solaris is shutting down.
XSCF> showdomainstatus -p 0
Logical Domain Name Status
primary Solaris powering down
4S-159-D0-G0 Solaris powering down
4S-159-D0-G1 Solaris powering down
4S-159-D0-G2 Solaris powering down
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ November 2014
74