7.4.3

System-stopped removal

This section describes the workflows for system-stopped/hot and system-stopped/
cold FRU removal. References to detailed descriptions are written in the workflow.
See any of them as required.
Figure 7-27     System-stopped/hot removal flow (for an internal disk or PCIe card)
1. Open rack door
2. Switch mode switch
3. Check operating condition of system and
I/O device usage status
4. Stop system
5. Lower cable support for maintenance on
PCIe card
6. Remove target FRU
7. Secure cable support after maintenance on
PCIe card
8. Diagnose chassis requiring maintenance
9. Confirm that there is no problem with chassis
after removal
10. Return mode switch to original mode
11. Start system
12. Close rack door
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ November 2014
162
Removal complete