                +   FRU-Part-Number:CA07361-D202   A0                                                   ;  
                +   Power_Supply_System:   ;  
                +   Memory_Size:320   GB;
------------------------ Omitted ------------------------
                PCI#0   Status:Normal;   Name_Property:pci;  
                        +   Vendor-ID:108e;   Device-ID:9020;  
                        +   Subsystem_Vendor-ID:0000;   Subsystem-ID:0000;  
                        +   Model:;  
                        +   Connection:7001;  
*                       PCIBOX#7001;   Status:Faulted;   Ver:1110h;   Serial:2121237001;  
                                +   FRU-Part-Number:;  
                                IOB   Status:Normal;   Serial:PP123403JE     ;  
                                        +   FRU-Part-Number:CA20365-B66X   008AG         ;  
                                LINKBOARD   Status:Normal;   Serial:PP1234026P     ;  
                                        +   FRU-Part-Number:CA20365-B60X   001AA         ;  
                                PCI#1   Name_Property:ethernet;  
                                        +   Vendor-ID:1077;   Device-ID:8000;  
                                        +   Subsystem_Vendor-ID:1077;   Subsystem-ID:017e;  
                                        +   Model:;
------------------------ Omitted -----------------------
 
- showstatus command
Execute the showstatus command to check the FRU status.
1.
Log in to the XSCF shell.
2.
Execute the showstatus command to check the status.
A faulty FRU is indicated by an asterisk (*) at the beginning of the line.
XSCF>   showstatus
        MBU   Status:Normal;
*               MEM#0A   Status:Faulted;
The FRU status is displayed after the "Status:" string.
Table 4-3
Table 4-3     FRU status
Display
Normal
Faulted
Degraded
Deconfigured
Maintenance
describes the FRU status.
Description
The unit is in the normal state.
The unit is faulty and is not operating.
A part of the unit has failed or degraded, but the unit is running.
Due to the failure or degradation of another unit, the target unit and
components of its underlying layer has been degraded, though there
is no problem in them.
Maintenance is being performed. The replacefru, addfru, or initbb
command is being executed.
Chapter 4 Preparation and Precautions for Maintenance