Fujitsu M10-4 Service Manual page 151

Hide thumbs Also See for Fujitsu M10-4:
Table of Contents

Advertisement

Table 7-14     System-stopped/cold replacement work procedure (for a building block configuration)
Item
Work procedure
1
Opening the rack door
2
Switching the mode switch on the
operation panel to Service mode
3
Checking the operating condition
of the system and the I/O device
usage status
4
Stopping the system
5
Releasing the chassis requiring
maintenance from the system
6
Enabling access to the FRU
requiring maintenance
7
Replacing a faulty FRU
8
Restoring the chassis requiring
maintenance
9
Incorporating the chassis requiring
maintenance into the system
10
Diagnosing the replacement FRU
11
Confirming that there is no
problem with the replacement FRU
12
Returning the mode switch on the
operation panel to Locked mode
13
Starting the system
14
Closing the rack door
*1 Simultaneous replacement of the CPU memory unit and PSU backplane unit is prohibited. To replace the CPU memory unit and PSU
backplane unit, first replace either of the units and perform the work up to "9. Confirming that there is no problem with the replacement
FRU." Then, return to "5. Enabling access to the FRU requiring maintenance," and replace the other unit.
*2 If a CPU memory unit lower is replaced in the system of the hardware RAID volume in a hardware RAID configuration using internal
disks, you need to reactivate the hardware RAID volume before performing the work in "12. Starting the system." For details, see "14.2.11
Re-enabling a hardware RAID volume" in the Fujitsu M10/SPARC M10 Systems System Operation and Administration Guide.
Reference
"5.2 Switching the Mode Switch to Service
"5.3 Checking the Operating Condition and Resource Usage
"5.6 Stopping the Entire
"5.8.1 Releasing of the SPARC M10-4S chassis (possible only in a
system with a building block
"5.9 Accessing an
FRU"
See the removal and installation procedures in the maintenance
procedures for each FRU (Chapters 8 to 16).
"Chapter 8 Maintaining the PCI Express
"Chapter 9 Maintaining the CPU Memory
"Chapter 10 Maintaining the Internal
"Chapter 11 Maintaining the Fan
"Chapter 12 Maintaining the Power Supply
"Chapter 13 Maintaining the PSU Backplane Unit/Operation
(*1)
"Chapter 14 Maintaining the Crossbar
"Chapter 15 Maintaining the Crossbar
"Chapter 16 Maintaining the XSCF BB Control
"6.1 Restoring the
Chassis"
"6.2.1 Incorporation of the SPARC M10-4S chassis (possible only in
a system with a building block
"6.3.1 Diagnosing the system
"6.3.2 Diagnosing the crossbar unit and crossbar
"4.2.2 Identifying a
failure" -
"6.6 Returning the Mode Switch to Locked
"6.8 Starting the Entire
System"
Mode"
System"
configuration)"
Cards"
Unit/Memory" (*1)(*2)
Disks"
Units"
Units"
Cables"
Units"
Cables"
configuration)"
board"
cables"
"Checking the FRU
status"
Mode"
Chapter 7 Maintenance Flow
Status"
Panel"
137