Returning The Mode Switch To Locked Mode; Powering On The Physical Partition Requiring Maintenance - Fujitsu M10-4 Service Manual

Hide thumbs Also See for Fujitsu M10-4:
Table of Contents

Advertisement

For details on the work, see the manual for the application being used.
2.
Confirm that the status of the physical I/O device is the same as before
maintenance.
#  ldm list-io
3.
Confirm that the operating condition of the logical domain remains unchanged.
#  ldm list-domain
6.6
Returning the Mode Switch to Locked
Mode
1.
Return the mode switch of the operation panel to Locked mode.
For a building block configuration, return the mode switches of the master
chassis and those chassis (BB-ID#00, #01) whose XSCFs are in the standby state
to Locked mode.
For details, see
Remarks - For a building block configuration with a connected crossbar box, return the
mode switches of BB-ID#80 and #81 of the crossbar box to Locked mode.
6.7
Powering On the Physical Partition
Requiring Maintenance
This section describes the procedure for powering on a physical partition requiring
maintenance.
1.
Switch the mode switches of the master chassis and those chassis
(BB-ID#00, #01) whose XSCFs are in the standby state to Locked mode.
2.
Log in to the XSCF shell.
3.
Execute the showstatus command to confirm that there is no problem with
the FRU after the completion of maintenance.
Nothing is displayed if it is normal.
XSCF>   showstatus
"2.3.2 Control function of the operation
panel."
Chapter 6 Restoring the System