Error Code Description
406D 0007 Attention handler detected fault in L3 VPD card 1. L3 VPD card
406D 000A Attention handler detected fault in primary I/O
book 1 (slot 0)
406D 000B Attention handler detected fault in secondary
I/O book (slot 1)
406D 000C Attention handler detected fault in I/O book 3
(slot 2)
406D 000D Attention handler detected fault in I/O book 4
(slot 3)
406D 000E CUoD capacity card
406D 0010 Attention handler detected fault in Memory book
(slot 0)
406D 0011 Attention handler detected fault in Memory book
(slot 1)
406D 0012 Attention handler detected fault in Memory book
(slot 2)
406D 0013 Attention handler detected fault in Memory book
(slot 3)
406D 0014 Attention handler detected fault in Memory book
(slot 4)
406D 0015 Attention handler detected fault in Memory book
(slot 5)
406D 0016 Attention handler detected fault in Memory book
(slot 6)
406D 0017 Attention handler detected fault in Memory book
(slot 7)
406D 00B0 Attention handler detected possible problem
with bus controller or CSP code
406D 00B1 Attention handler detected possible problem
with bus controller
Action/
Possible Failing FRU
Location: U1.18-P1-H2.1
(Order the L3 cache module FRU to obtain
a new L3 VPD card. Return the L3 cache
module that was included in the FRU kit,
and the failing L3 VPD card as "new
defective".)
2. Primary I/O book
Location: U1.18-P1-H2
Go to "MAP 1540: Problem Isolation
Procedures" on page 298.
Go to "MAP 1540: Problem Isolation
Procedures" on page 298.
Go to "MAP 1540: Problem Isolation
Procedures" on page 298.
Go to "MAP 1540: Problem Isolation
Procedures" on page 298.
1. Replace the CUoD capacity card
Location: U1.18-P1-H2.2
2. Ask the customer to reenter the CUoD
activation keys.
Memory book (slot 0)
Location: U1.18-P1-M2
Memory book (slot 1)
Location: U1.18-P1-M3
Memory book (slot 2)
Location: U1.18-P1-M7
Memory book (slot 3)
Location: U1.18-P1-M6
Memory book (slot 4)
Location: U1.18-P1-M4
Memory book (slot 5)
Location: U1.18-P1-M8
Memory book (slot 6)
Location: U1.18-P1-M5
Memory book (slot 7)
Location: U1.18-P1-M1
1. Check for system firmware updates.
2. Primary I/O book,
Location: U1.18-P1-H2
3. Call service support.
1. Check for system firmware updates.
2. Primary I/O book,
Location: U1.18-P1-H2
3. Call service support.
Chapter 5. Error Code to FRU Index
613