IBM pSeries 690 Service Manual page 518

Hide thumbs Also See for pSeries 690:
Table of Contents

Advertisement

Error Code Description
4064 0C12 Processor subsystem tests detected mismatch
between MCM 1 and VPD card
4064 0C13 Processor subsystem tests detected mismatch
between MCM 3 and VPD card
4064 0CA5 Processor subsystem tests detected invalid
processor subsystem configuration
4064 0CA6 Processor subsystem tests detected no usable
main storage
4064 0CA9 Processor subsystem tests detected
configuration error with processor memory
4064 0D00 Processor subsystem tests detected fault in L3
cache module 0
4064 0D01 Processor subsystem tests detected fault in L3
cache module 1
4064 0D02 Processor subsystem tests detected fault in L3
cache module 2
4064 0D03 Processor subsystem tests detected fault in L3
cache module 3
4064 0D04 Processor subsystem tests detected fault in L3
cache module 4
4064 0D05 Processor subsystem tests detected fault in L3
cache module 5
4064 0D06 Processor subsystem tests detected fault in L3
cache module 6
4064 0D07 Processor subsystem tests detected fault in L3
cache module 7
4064 0D08 Processor subsystem tests detected fault in L3
cache module 8
4064 0D09 Processor subsystem tests detected fault in L3
cache module 9
4064 0D0A Processor subsystem tests detected fault in L3
cache module 10
4064 0D0B Processor subsystem tests detected fault in L3
cache module 11
4064 0D0C Processor subsystem tests detected fault in L3
cache module 12
4064 0D0D Processor subsystem tests detected fault in L3
cache module 13
4064 0D0E Processor subsystem tests detected fault in L3
cache module 14
4064 0D0F Processor subsystem tests detected fault in L3
cache module 15
498
Eserver pSeries 690 Service Guide
Action/
Possible Failing FRU
Plugging error with FRU kit
Location: U1.18-P1-C3 and U1.18-P1-H2.5
Plugging error with FRU kit
Location: U1.18-P1-C2 and U1.18-P1-H2.6
Verify that MCMs, memory books, and L3
modules are correctly configured.
Reboot the system in slow mode to isolate the
failure.
Reboot the system in slow mode to isolate the
failure.
L3 cache module 0 and L3 VPD card
Location: U1.18-P1-C6 and U1.18-P1-H2.1
L3 cache module 1 and L3 VPD card
Location: U1.18-P1-C7 and U1.18-P1-H2.1
L3 cache module 2 and L3 VPD card
Location: U1.18-P1-C11 and U1.18-P1-H2.1
L3 cache module 3 and L3 VPD card
Location: U1.18-P1-C10 and U1.18-P1-H2.1
L3 cache module 4 and L3 VPD card
Location: U1.18-P1-C8 and U1.18-P1-H2.1
L3 cache module 5 and L3 VPD card
Location: U1.18-P1-C20 and U1.18-P1-H2.1
L3 cache module 6 and L3 VPD card
Location: U1.18-P1-C16 and U1.18-P1-H2.1
L3 cache module 7 and L3 VPD card
Location: U1.18-P1-C12 and U1.18-P1-H2.1
L3 cache module 8 and L3 VPD card
Location: U1.18-P1-C19 and U1.18-P1-H2.1
L3 cache module 9 and L3 VPD card
Location: U1.18-P1-C18 and U1.18-P1-H2.1
L3 cache module 10 and L3 VPD card
Location: U1.18-P1-C14 and U1.18-P1-H2.1
L3 cache module 11 and L3 VPD card
Location: U1.18-P1-C15 and U1.18-P1-H2.1
L3 cache module 12 and L3 VPD card
Location: U1.18-P1-C17 and U1.18-P1-H2.1
L3 cache module 13 and L3 VPD card
Location: U1.18-P1-C5 and U1.18-P1-H2.1
L3 cache module 14 and L3 VPD card
Location: U1.18-P1-C9 and U1.18-P1-H2.1
L3 cache module 15 and L3 VPD card
Location: U1.18-P1-C13 and U1.18-P1-H2.1