IBM pSeries 690 Service Manual page 432

Hide thumbs Also See for pSeries 690:
Table of Contents

Advertisement

Error Code Description
1016 F526 An N+1 boundary (DCA or fan) has dropped to
N-mode status in the third I/O subsystem,
location: U1.1.
1016 xx11 third I/O subsystem in primary rack, DCA-1
1016 xx13 Seeprom fault on DCA-1 in third I/O subsystem
in primary rack
1016 xx15 Third I/O subsystem in primary rack, DCA-1,
cable fault
1016 xx17 Problem with fan 1 and fan 3 in third I/O
subsystem in primary rack
1016 xx21 Third I/O subsystem in primary rack, DCA-2
1016 xx23 Seeprom fault on DCA-2 in third I/O subsystem
in primary rack
1016 xx25 Third I/O subsystem in primary rack, DCA-2,
cable fault
1016 xx27 Problem with fan 2 and fan 4 in third I/O
subsystem in primary rack
1016 xx31 Third I/O subsystem in primary rack, I/O
subsystem backplane 1 fault
1016 xx33 Seeprom fault on I/O subsystem backplane 1 in
third I/O subsystem in primary rack
1016 xx41 Third I/O subsystem in primary rack, I/O
subsystem backplane 2 fault
1016 xx43 Seeprom fault on I/O subsystem backplane 2 in
third I/O subsystem in primary rack
1016 xx51 Third I/O subsystem in primary rack, DASD
backplane 1 fault
1016 xx53 Seeprom fault on DASD backplane 1 in third I/O
subsystem in primary rack
412
Eserver pSeries 690 Service Guide
Action/
Possible Failing FRU
This is normally an informational message. It
should be accompanied by other error codes
that more precisely indicate where the failure is.
Examine the service processor error log. If there
are no other power-related error codes (in the
time frame in which this code was generated) in
the service processor error log, the FRU
indicated with this error code, if any, should be
replaced.
U1.1-V1
U1.1-V1
Go to "MAP 1520: Power" on page 190 with
these pairs of location codes:
1. U1.1-V1/Q1 and U1.35-P2-X3/Q5
2. U1.1-V1/Q2 and U1.35-P1-X3/Q5
1. DCA-1
Location U1.1–V1
2. Fan 1,
Location U1.1–F1
3. Fan 3,
Location U1.1–F3
U1.1-V2
U1.1-V2
Go to "MAP 1520: Power" on page 190 with
these pairs of location codes:
1. U1.1-V2/Q1 and U1.35-P2-X3/Q6
2. U1.1-V2/Q2 and U1.35-P1-X3/Q6
1. DCA-2
Location U1.1–V2
2. Fan 2,
Location U1.1F2
3. Fan 4,
Location U1.1–F4
U1.1-P1
U1.1-P1
U1.1-P2
U1.1-P2
U1.1-P3
U1.1-P3

Advertisement