Error Code Description
406B 0007 Wire tests detected fault in L3 VPD card
406B 000A Wire tests detected fault in primary I/O book 1
(slot 0)
406B 000B Wire tests detected fault in secondary I/O book
(slot 1)
406B 000C Wire tests detected fault in I/O book 3 (slot 2)
406B 000D Wire tests detected fault in I/O book 4 (slot 3)
406B 000E CUoD capacity card
406B 0010 Wire tests detected fault in Memory book (slot
0)
406B 0011 Wire tests detected fault in Memory book (slot
1)
406B 0012 Wire tests detected fault in Memory book (slot
2)
406B 0013 Wire tests detected fault in Memory book (slot
3)
406B 0014 Wire tests detected fault in Memory book (slot
4)
406B 0015 Wire tests detected fault in Memory book (slot
5)
406B 0016 Wire tests detected fault in Memory book (slot
6)
406B 0017 Wire tests detected fault in Memory book (slot
7)
406B 00B0 Wire tests detected possible problem with bus
controller or CSP code
406B 00B1 Wire tests detected possible problem with bus
controller
Action/
Possible Failing FRU
1. L3 VPD card
Location: U1.18-P1-H2.1
(Order the L3 cache module FRU to obtain
a new L3 VPD card. Return the L3 cache
module that was included in the FRU kit,
and the failing L3 VPD card as "new
defective".)
2. Primary I/O book
Location: U1.18-P1-H2
Go to "MAP 1540: Problem Isolation
Procedures" on page 298.
Go to "MAP 1540: Problem Isolation
Procedures" on page 298.
Go to "MAP 1540: Problem Isolation
Procedures" on page 298.
Go to "MAP 1540: Problem Isolation
Procedures" on page 298.
1. Replace the CUoD capacity card
Location: U1.18-P1-H2.2
2. Ask the customer to reenter the CUoD
activation keys.
Memory book (slot 0)
Location: U1.18-P1-M2
Memory book (slot 1)
Location: U1.18-P1-M3
Memory book (slot 2)
Location: U1.18-P1-M7
Memory book (slot 3)
Location: U1.18-P1-M6
Memory book (slot 4)
Location: U1.18-P1-M4
Memory book (slot 5)
Location: U1.18-P1-M8
Memory book (slot 6)
Location: U1.18-P1-M5
Memory book (slot 7)
Location: U1.18-P1-M1
1. Check for system firmware updates.
2. Primary I/O book,
Location: U1.18-P1-H2
3. Call service support.
1. Check for system firmware updates.
2. Primary I/O book,
Location: U1.18-P1-H2
3. Call service support.
Chapter 5. Error Code to FRU Index
585