Error Code Description
1014 BF06 Unable to resolve the chassis VPD in an I/O
subsystem
1014 CD96 A power short has been detected in the DASD
subsystem in an I/O drawer.
1014 CDA6 A power short has been detected in the DASD
subsystem in an I/O drawer.
1014 CDB6 A power short has been detected in the DASD
subsystem in an I/O drawer.
1014 CDC6 A power short has been detected in the DASD
subsystem in an I/O drawer.
1014 F4x6 Hardware configuration does not support
N-mode power.
1014 F516 An N+1 boundary (DCA or fan) has dropped to
N-mode status in the first I/O subsystem,
location: U1.9.
1014 F526 An N+1 boundary (DCA or fan) has dropped to
N-mode status in the first I/O subsystem,
location: U1.9.
1014 xx11 First I/O subsystem in primary rack, DCA-1
1014 xx13 Seeprom fault on DCA-1 in first I/O subsystem in
primary rack
1014 xx15 First I/O subsystem in primary rack, DCA-1,
cable fault
1014 xx17 Problem with fan 1 and fan 3 in first I/O
subsystem in primary rack
Action/
Possible Failing FRU
The chassis VPD in the I/O subsystem drawer
identified by the location code could not be
resolved. This may be an indication that more
than one FRU in the drawer was replaced during
a service action. If this is the case, reinstall the
original FRUs in the drawer, then replace the
FRUs one at a time.
If only one FRU was replaced and this error
code occurred, call service support.
Go to "MAP 1520: Power" on page 190.
Go to "MAP 1520: Power" on page 190.
Go to "MAP 1520: Power" on page 190.
Go to "MAP 1520: Power" on page 190.
Call Service Support
This is normally an informational message. It
should be accompanied by other error codes
that more precisely indicate where the failure is.
Examine the service processor error log. If there
are no other power-related error codes (in the
time frame in which this code was generated) in
the service processor error log, the FRU
indicated with this error code, if any, should be
replaced.
This is normally an informational message. It
should be accompanied by other error codes
that more precisely indicate where the failure is.
Examine the service processor error log. If there
are no other power-related error codes (in the
time frame in which this code was generated) in
the service processor error log, the FRU
indicated with this error code, if any, should be
replaced.
U1.9-V1
U1.9-V1
Go to "MAP 1520: Power" on page 190 with
these pairs of location codes:
1. U1.9-V1/Q1 and U1.35-P2-X3/Q1
2. U1.9-V1/Q2 and U1.35-P1-X3/Q1
1. DCA-1
Location U1.9–V1
2. Fan 1,
Location U1.9–F1
3. Fan 3,
Location U1.9–F3
Chapter 5. Error Code to FRU Index
405