IBM pSeries 690 Service Manual page 535

Hide thumbs Also See for pSeries 690:
Table of Contents

Advertisement

Error Code Description
4066 0007 Scan interface basic assurance tests detected
fault in L3 VPD card
4066 000A Scan interface basic assurance tests detected
fault in primary I/O book 1 (slot 0)
4066 000B Scan interface basic assurance tests detected
fault in secondary I/O book (slot 1)
4066 000C Scan interface basic assurance tests detected
fault in I/O book 3 (slot 2)
4066 000D Scan interface basic assurance tests detected
fault in I/O book 4 (slot 3)
4066 000E CUoD capacity card
4066 0010 Scan interface basic assurance tests detected
fault in Memory book (slot 0)
4066 0011 Scan interface basic assurance tests detected
fault in Memory book (slot 1)
4066 0012 Scan interface basic assurance tests detected
fault in Memory book (slot 2)
4066 0013 Scan interface basic assurance tests detected
fault in Memory book (slot 3)
4066 0014 Scan interface basic assurance tests detected
fault in Memory book (slot 4)
4066 0015 Scan interface basic assurance tests detected
fault in Memory book (slot 5)
4066 0016 Scan interface basic assurance tests detected
fault in Memory book (slot 6)
4066 0017 Scan interface basic assurance tests detected
fault in Memory book (slot 7)
4066 00B0 Possible problem with bus controller or CSP
code
4066 00B1 Possible problem with bus controller
Action/
Possible Failing FRU
1. L3 VPD card
Location: U1.18-P1-H2.1
(Order the L3 cache module FRU to obtain
a new L3 VPD card. Return the L3 cache
module that was included in the FRU kit,
and the failing L3 VPD card as "new
defective".)
2. Primary I/O book
Location: U1.18-P1-H2
Go to "MAP 1540: Problem Isolation
Procedures" on page 298.
Go to "MAP 1540: Problem Isolation
Procedures" on page 298.
Go to "MAP 1540: Problem Isolation
Procedures" on page 298.
Go to "MAP 1540: Problem Isolation
Procedures" on page 298.
1. Replace the CUoD capacity card
Location: U1.18-P1-H2.2
2. Ask the customer to reenter the CUoD
activation keys.
Memory book (slot 0)
Location: U1.18-P1-M2
Memory book (slot 1)
Location: U1.18-P1-M3
Memory book (slot 2)
Location: U1.18-P1-M7
Memory book (slot 3)
Location: U1.18-P1-M6
Memory book (slot 4)
Location: U1.18-P1-M4
Memory book (slot 5)
Location: U1.18-P1-M8
Memory book (slot 6)
Location: U1.18-P1-M5
Memory book (slot 7)
Location: U1.18-P1-M1
1. Check for system firmware updates.
2. Primary I/O book,
Location: U1.18-P1-H2
3. Call service support.
1. Check for system firmware updates.
2. Primary I/O book,
Location: U1.18-P1-H2
3. Call service support.
Chapter 5. Error Code to FRU Index
515

Advertisement

Table of Contents
loading

Table of Contents