Error Code Description
1017 xx25 Fourth I/O subsystem in primary rack no IBFs
1017 xx27 Problem with fan 2 and fan 4 in fourth I/O
subsystem (no IBF installed) in primary rack
1017 xx31 Fourth I/O subsystem in primary rack, I/O
subsystem backplane 1 fault
1017 xx33 Seeprom fault on I/O subsystem backplane 1 in
fourth I/O subsystem (no IBF) in primary rack
1017 xx41 Fourth I/O subsystem in primary rack, I/O
subsystem backplane 2 fault
1017 xx43 Seeprom fault on I/O subsystem backplane 2 in
fourth I/O subsystem (no IBF) in primary rack
1017 xx51 Fourth I/O subsystem in primary rack, DASD
backplane 1 fault
1017 xx53 Seeprom fault on DASD backplane 1 in fourth
I/O subsystem (no IBF) in primary rack
1017 xx61 Fourth I/O subsystem in primary rack, DASD
backplane 2 fault
1017 xx63 Seeprom fault on DASD backplane 2 in fourth
I/O subsystem (no IBF) in primary rack
1017 xx71 Fourth I/O subsystem in primary rack, DASD
backplane 3 fault
1017 xx73 Seeprom fault on DASD backplane 3 in fourth
I/O subsystem (no IBF) in primary rack
1017 xx81 Fourth I/O subsystem in primary rack, DASD
backplane 4 fault
1017 xx83 Seeprom fault on DASD backplane 4 in fourth
I/O subsystem (no IBF) in primary rack
101A 0856 BPR 1A communications fault
101A 0866 BPR 2A communications fault
416
Eserver pSeries 690 Service Guide
Action/
Possible Failing FRU
If there is no DCA in U1.18-P1-V8, primary rack,
no IBFs, go to "MAP 1520: Power" on
page 190with these pairs of location codes:
1. U1.13-V2/Q1 and U1.35-P2-X3/Q8
2. U1.13-V2/Q2 and U1.35-P1-X3/Q8
If there is a 6th DCA in U1.18-P1-V8, go to
"MAP 1520: Power" on page 190 with these
pairs of location codes:
1. U1.13-V2/Q1 and U1.35-P2-X2/Q10
2. U1.13-V2/Q2 and U1.35-P1-X2/Q10
1. DCA-2
Location U1.13-V2
2. Fan 2,
Location U1.13-F2
3. Fan 4,
Location U1.13-F4
U1.13-P1
U1.13-P1
U1.13-P2
U1.13-P2
U1.13-P3
U1.13-P3
U1.13-P4
U1.13-P4
U1.13-P5
U1.13-P5
U1.13-P6
U1.13-P6
Go to "MAP 1523: There Is a Bulk Power
Regulator (BPR) Communications Fault" on
page 198.
Go to "MAP 1523: There Is a Bulk Power
Regulator (BPR) Communications Fault" on
page 198.