Error Code Description
4B25 25C1 Processor subsystem and display alter tests
detected fault in 1.0 GHz clock card
4B25 25C7 Processor subsystem and display alter tests
detected fault in 4-way processor MCM
4B25 25C8 Processor subsystem and display alter tests
detected fault in 4-way processor MCM
4B25 25CF Processor subsystem detected fault in 8-way
processor MCM
4B25 25D3 Processor subsystem and display alter tests
detected fault in 8-way processor MCM with
VPD card
4B25 25D5 Processor subsystem and display alter tests
detected fault in 8-way processor MCM with
VPD card (8-, 16-, or 24-way)
4B25 25D7 Fault in 4-way processor MCM detected
4B25 25D8 Fault in 4-way processor MCM detected
4B25 25E5 Processor subsystem detected fault in 4-way
processor MCM
4B25 25E9 Processor subsystem detected fault in 8-way
processor MCM
4B25 28B0 Processor subsystem and display alter tests
detected fault in I/O subsystem PCI backplane
4B25 28B1 Processor subsystem and display alter tests
detected fault in I/O subsystem DASD
backplane
4B25 526B Fault detected in 4-way or 8-way CUoD MCM
4B25 526C Fault detected in 4-way or 8-way CUoD MCM
4B25 526D Fault detected in 4-way or 8-way CUoD MCM
4B25 526D Fault detected in 4-way or 8-way CUoD MCM
4B26 248B Processor subsystem and scan interface basic
assurance tests detected fault in operator panel
714
Eserver pSeries 690 Service Guide
Action/
Possible Failing FRU
Clock card
Location: U1.18-P1-X5
Go to "MAP 1540: Problem Isolation
Procedures" on page 298 to isolate the failing
component.
Go to "MAP 1540: Problem Isolation
Procedures" on page 298 to isolate the failing
component.
Go to "MAP 1540: Problem Isolation
Procedures" on page 298 to isolate the failing
component.
Go to "MAP 1540: Problem Isolation
Procedures" on page 298 to isolate the failing
component.
Go to "MAP 1540: Problem Isolation
Procedures" on page 298 to isolate the failing
component.
Go to "MAP 1540: Problem Isolation
Procedures" on page 298 to isolate the failing
component.
Go to "MAP 1540: Problem Isolation
Procedures" on page 298 to isolate the failing
component.
Go to "MAP 1540: Problem Isolation
Procedures" on page 298 to isolate the failing
component.
Go to "MAP 1540: Problem Isolation
Procedures" on page 298 to isolate the failing
component.
I/O subsystem PCI backplane at location
specified in error code
I/O subsystem DASD backplane at location
specified in error code
Go to "MAP 1540: Problem Isolation
Procedures" on page 298 to isolate the failing
component.
Go to "MAP 1540: Problem Isolation
Procedures" on page 298 to isolate the failing
component.
Go to "MAP 1540: Problem Isolation
Procedures" on page 298 to isolate the failing
component.
Go to "MAP 1540: Problem Isolation
Procedures" on page 298 to isolate the failing
component.
Operator panel
Location: U1.17-L1